✅A set of commercial firmware for chip tuning UAZ cars with ECU M (E) 17.9.7 GAS + OFFIMMO from Paulus and DiK PROGRAM AUTO DIAGNOSTIC OBD2 SOFTWARES
✅A set of commercial firmware for chip tuning UAZ cars with ECU M (E) 17.9.7 GAS + OFFIMMO from Paulus and DiK PROGRAM AUTO DIAGNOSTIC OBD2 SOFTWARES

✅A set of commercial firmware for chip tuning UAZ cars with ECU M (E) 17.9.7 GAS + OFFIMMO from Paulus and DiK PROGRAM

Regular price
£16.00
Sale price
£14.00
Tax included. Shipping calculated at checkout.

 

INSTANT DOWNLOAD LINK WILL BE SENT !

NO CD OR DVD INCLUDED !   

Packages of modified firmware from Paulus and DiK to Bosch ME17.9.7 control units (E-GAS), Bosch M17.9.7 UAZ.
Bundled tuning firmware for all known software with electronic and mechanical choke.

In the NIvers folder of the firmware with the software disabled request to the immobilizer, both in stock and in the tuning versions of the firmware.

In these firmware, as in all of Pasha, there is an increase in power, as well as a decrease in fuel consumption during cruising modes.

The UAZ M (E) 17.9.7 firmware package from Paulus GAS + OFFIMMO includes the following firmware sets:
GBO versions
Egas MR 3xRej

GBO4_MR_PropanMetan_1037393797_VM31B114.bin
GBO4_MR_PropanMetan_1037395102 -VM31B122.bin
GBO4_MR_PropanMetan_1037504368_VM31B124.bin
GBO4_MR_PropanMetan_1037516412 _VM31B126.bin

Mgas MR 3xRej
GBO4_MR_PropanMetan_1037506958_VM32B176.bin
GBO4_MR_PropanMetan_1037509718-VM32B181.bin
GBO4_MR_PropanMetan_1037510612_VM32B185.bin
GBO4_MR_PropanMetan_1037516458_VM32B187.bin
3х режимные газовые прошивки от Paulus и DiK.
!!!Заливать строго полностью прошивку!!!
Реализована идентификация режимов, для удобства контроля переключения.

NIvers Stok OFFIMMO
E-Gaz

1037393797_VM31B114.bin
1037395102_VM31B122.bin
1037504368_VM31B124.bin
1037516412-VM31B126.bin
1037521336_VM35B292.bin
Стоковые версии без проблем с ИММ.

NIvers UAZ ME17 складка Upd5 OFFIMMO
E-Gaz
VM31B114 f

1037393797_VM31B114.bin
MR3x_GBO4_PropanMetan_1037393797_VM31B114.bin
MR3x_GBO4_Santeh_1037393797_VM31B114_v2.bin
Startpower 1037393797_VM31B114 e2 v2.bin

VM31B122 f
1037395102_VM31B122.bin
MR3x_GBO4_PropanMetan_1037395102 -VM31B122.bin
MR3x_GBO4_Santeh_1037395102_VM31B122_v2.bin
Startpower 1037395102 -VM31B122 e2 .bin

VM31B124 f
1037504368_VM31B124.bin
MR3x_GBO4_PropanMetan_1037504368_VM31B124.bin
MR3x_GBO4_Santeh_1037504368_VM31B124_v2.bin
Startpower 1037504368_VM31B124 e2.bin

VM31B126 f
1037516412-VM31B126.bin
MR3x_GBO4_PropanMetan_1037516412 _VM31B126.bin
MR3x_GBO4_Santeh_1037516412 _VM31B126_v2.bin
Startpower 1037516412 _VM31B126 e2 .bin
Startpower 1037516412 _VM31B126.bin

VM35B292 f
1037521336_VM35B292.bin
MR3x_GBO4_Santeh_1037521336 _VM35B292.bin
Startpower 2012 VM35B292 e2.bin
Startpower 2012 VM35B292.bin
Версии без проблем с ИММ.

3х режимные газовые прошивки от Paulus и DiK.
!!!Заливать строго полностью прошивку!!!
Реализована идентификация режимов, для удобства контроля переключения.


Tuning GBO
E-Gaz
VM31B114 f

1037393797_VM31B114.bin
MR3x_GBO4_PropanMetan_1037393797_VM31B114.bin
MR3x_GBO4_Santeh_1037393797_VM31B114_v2.bin
Startpower 1037393797_VM31B114 e2 v2.bin

VM31B122 f
1037395102_VM31B122.bin
MR3x_GBO4_PropanMetan_1037395102 -VM31B122.bin
MR3x_GBO4_Santeh_1037395102_VM31B122_v2.bin
Startpower 1037395102 -VM31B122 e2 .bin

VM31B124 f
1037504368_VM31B124.bin
MR3x_GBO4_PropanMetan_1037504368_VM31B124.bin
MR3x_GBO4_Santeh_1037504368_VM31B124_v2.bin
Startpower 1037504368_VM31B124 e2.bin

VM31B126 f
1037516412-VM31B126.bin
MR3x_GBO4_PropanMetan_1037516412 _VM31B126.bin
MR3x_GBO4_Santeh_1037516412 _VM31B126_v2.bin
Startpower 1037516412 _VM31B126 e2 .bin
Startpower 1037516412 _VM31B126.bin

VM35B292 f
1037521336_VM35B292.bin
MR3x_GBO4_Santeh_1037521336 _VM35B292.bin
Startpower 2012 VM35B292 e2.bin
Startpower 2012 VM35B292.bin

M-Gaz
VM32B176 f

1037506958_VM32B176.bin
MR3x_GBO4_PropanMetan_1037506958_VM32B176.bin
MR3x_GBO4_Santeh_1037506958_VM32B176_v2.bin
Startpower 1037506958_VM32B176 e2.bin

VM32B181 f
1037509718-VM32B181.bin
MR3x_GBO4_PropanMetan_1037509718-VM32B181.bin
MR3x_GBO4_Santeh_1037509718-VM32B181_v2.bin
Startpower 1037509718-VM32B181 e2.bin

VM32B185 f
1037510612_VM32B185.bin
MR3x_GBO4_PropanMetan_1037510612_VM32B185.bin
MR3x_GBO4_Santeh_1037510612_VM32B185_v2.bin
Startpower 1037510612_VM32B185 e2.bin

VM32B187 f
1037516458_VM32B187.bin
MR3x_GBO4_PropanMetan_1037516458_VM32B187.bin
MR3x_GBO4_PropanMetan_1037516458_VM32B187_v2(ot6000).bin
MR3x_GBO4_Santeh_1037516458_VM32B187_v2(ot6000).bin
Startpower 1037516458_VM32B187 e2.bin
Startpower 1037516458_VM32B187 e2_ot6000.bin
Startpower 1037516458_VM32B187.bin
Startpower 1037516458_VM32B187_ot6000.bin

VM36B290_f
1037522304_VM36B290.bin
MR3x_GBO4_santeh_Startpower_2012_VM36B290.bin
Startpower 2012 VM36B290 e2 .bin
Startpower 2012 VM36B290.bin
3 regime gas firmware from Paulus and DiK.
!!! Fill the firmware completely !!!
Implemented identification modes for easy control of switching.

Calibrations: Paulus

All kit firmware in decrypt!
Startpower - only petrol tuning.
1037516412 _VM31B126 - identifier.
E2 - Euro toxicity norms 2.
no_Immo - the request to the immobilizer is disabled.
MR3x - 3 regime gas firmware.
GBO4_Santeh - 1st mode gasoline, 2nd mode HBO4 propane, 3rd mode HBO "plumbing" propane.
GBO4_PropanMetan - 1st mode gasoline, 2nd mode HBO4 propane, 3rd mode HBO4 methane.

Latest software is valid to replace all previous ones. Egas - VM31B126, Mgas - VM32B187, Mgas (DAD) - VM36B290, gas (DAD) - VM35B292.
Ways to switch the modes of versions MR3x_GBO4_Santeh ...:
1st mode gasoline - normal operation of the DTV sensor (from 0.2 to 3.1 volts)
2nd mode HBO4 propane - DTV signal is pulled to the ground (less than 0.2 volts)
The third mode HBO "plumbing" propane - Signal DTV "in the air" (more than 3.1 volts), the nozzles are programmatically disabled in the Gas mode, the control of the fuel pump is disconnected, there is no software to turn off the gas pump.

Ways to switch the modes of versions MR3x_GBO4_PropanMetan ...:
1st mode gasoline - normal operation of the DTV sensor (from 0.2 to 3.1 volts)
2nd mode HBO4 propane - DTV signal is pulled to the ground (less than 0.2 volts)
3rd mode HBO4 methane - Signal DTV "in the air" (more than 3.1 volts)
Click to edit the product in Ali Orders.
Note: only show for shop owner